Bid No | 41 |
---|---|
Item for Bid | Technical consultation for the Passive Condensate Heat Exchanger |
Notice Date | 2012-07-18 |
Deadline for Bid Submission | 2012-07-22 |
Content |
<ul>
<li><font face="Times New Roman">Task 1. Review of Passive Condensate Heat Exchanger Sizing in KEPCO E&C Calculation</font><font face="Times New Roman"><br /> Passive Condensate Heat Exchanger Sizing calculation provided by KEPCO-E&C will be reviewed.<br /> - Review of compare with PASCAL Test*<br /> - Determine of Heat Transfer Area<br /> - Determine of PCHX outside fouling factor<br /> - Determine of PCHX inside fouling factor<br /> - Determine of PCHX plugging margin<br /> - Determine of Overall Heat Transfer Coefficient(W/m2K) and Heat Transfer(Q)</font> </li> </ul> <p><font face="Times New Roman"> * PASCAL Test was performed at KAERI(Korea Atomic Energy Research Institute) in KOREA. <br /> </font></p> <ul> <li><font face="Times New Roman">Task 2. Design Review Meeting<br /> Based on an initial review of Passive Condensate Heat Exchanger Sizing in Task 1, a MPR review team will be established. This will include a Design Review Coordinator, a Cognizant Engineer, and a supporting team of reviewers.<br /> MPR shall host a 5 day meeting at the MPR offices in Washington DC with KEPCO engineers to conduct a review of the PAFS.<br /> - KEPCO Engineers would provide an overview of the design<br /> - MPR engineers would present results of review of KEPCO calculation and Plan <br /> The extent of the design review will be limited to the contents of the KEPCO calculation.</font> </li> </ul> <p> </p> <ul> <li><font face="Times New Roman">Task 3. Final report documentation and results<br /> The final report shall include:<br /> - A review of Passive Condensate Heat Exchanger Sizing<br /> - A review summary<br /> - Conclusions and recommendations from the review. This section would identify problem areas<br /> - All presentations made during the review</font> </li> </ul> <p> </p> |
Attachments |
-
- Bid No
- 41
- Item for Bid
- Technical consultation for the Passive Condensate Heat Exchanger
- Notice Date
- 2012-07-18
- Deadline for Bid Submission
- 2012-07-22
- Content
-
<ul>
<li><font face="Times New Roman">Task 1. Review of Passive Condensate Heat Exchanger Sizing in KEPCO E&C Calculation</font><font face="Times New Roman"><br />
Passive Condensate Heat Exchanger Sizing calculation provided by KEPCO-E&C will be reviewed.<br />
- Review of compare with PASCAL Test*<br />
- Determine of Heat Transfer Area<br />
- Determine of PCHX outside fouling factor<br />
- Determine of PCHX inside fouling factor<br />
- Determine of PCHX plugging margin<br />
- Determine of Overall Heat Transfer Coefficient(W/m2K) and Heat Transfer(Q)</font> </li>
</ul>
<p><font face="Times New Roman"> * PASCAL Test was performed at KAERI(Korea Atomic Energy Research Institute) in KOREA. <br />
</font></p>
<ul>
<li><font face="Times New Roman">Task 2. Design Review Meeting<br />
Based on an initial review of Passive Condensate Heat Exchanger Sizing in Task 1, a MPR review team will be established. This will include a Design Review Coordinator, a Cognizant Engineer, and a supporting team of reviewers.<br />
MPR shall host a 5 day meeting at the MPR offices in Washington DC with KEPCO engineers to conduct a review of the PAFS.<br />
- KEPCO Engineers would provide an overview of the design<br />
- MPR engineers would present results of review of KEPCO calculation and Plan <br />
The extent of the design review will be limited to the contents of the KEPCO calculation.</font> </li>
</ul>
<p> </p>
<ul>
<li><font face="Times New Roman">Task 3. Final report documentation and results<br />
The final report shall include:<br />
- A review of Passive Condensate Heat Exchanger Sizing<br />
- A review summary<br />
- Conclusions and recommendations from the review. This section would identify problem areas<br />
- All presentations made during the review</font> </li>
</ul>
<p> </p>
- Attachments
Prev List | Technical consultation on the Two-Phase Natural Circulation Instability Analysis |
---|---|