본문으로 바로가기

New Start, New Standard
Comments on Sole Source Contract

Customer CenterComments on Sole Source Contract
Notice No. 415
Notice Date 2019-11-18
Contract Title Technical Consultation on HBN 3,4 & HUN 3,4 SC/SI System Replaced Valve Weld Leak-Before-Break(LBB) Evaluation
Contract Overview - Selection of archival material for material testing
- Consideration of long-term aging effects in material testing
- Consideration of material temperature dependency in material testing
- Specimen orientation
Estimated Value USD 54,000
Expected Completion Date March 31, 2020
Reason(s) for the Sole Sourcing It is necessary for the contractor to have technical knowledge
about leak-before-break evaluation methodology and technical
basis.
And contractor should have source technology for PICEP code
that is used for LBB evaluation.
SI is only contractor that can meet the above requirements
because source technology of PICEP code is property of SI.
Company to be Contracted Structural Integrity Associates, Inc.(SI)
Name C.S. Park
Dept O&M Department
Tel 82-54-421-3973
email centralpark@kepco-enc.com
Attachments
  • pdf 첨부파일 detail information(LBB Evaluation).pdf (73.82KB) Download