Bid No 48
Item for Bid US-APR1400 Sump Strainer Technical Support
Notice Date 2013-04-08
Deadline for Bid Submission 2013-04-12
Content

Task 1. Performance Test:


       ○ Head loss tests, vortex test, and bypass test for fiber for APR

        1400 IRWST sump strainer performance shall be performed


- Clean head loss test


 - Full debris-load test


 - Thin-bed test


 - Chemical effects test


 - Vortex test


- Bypass test


Task 2. Supporting response to NRC RAIs related to IRWST sump strainer   performance testing


Task 3. Documentation of Technical Service Results


       ○ Technical report including the followings for APR 1400 IRWST sump

         strainer performance shall be provided


- Test Plan


- Test Procedure


- Test Results


- Strainer Size